Advertisement

Alarm messages
2 Mbit/s extension board failure - protected
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
Note(s)
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
E12XcEQF
The 2 Mbit/s extension board is defective.
Equipment
equipment
Deferred
Reported
The red "Fault" LED is lit.
The on board self-test circuitry indicates that an essential function of the unit
fails.
Replace the 2 Mbit/s extension board.
As 1643 AM and 1643 AMS systems do not support hardware protection,
E12XcEQF, and E12XcUPF are always reported simultaneously as a reminder
that a hardware failure is service affecting.
Alcatel-Lucent - Proprietary
See notice on first page
1-27