Alarm messages
VC-3 Near-end errored seconds threshold crossing 24-hrs
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-260
VC3NEScTHR24
The VC-3 near-end errored seconds counter exceeded the provisioned threshold
during a 24-hour monitoring period.
Quality of service (performance monitoring)
sdhLOPath
Information
Not Reported
–
Possible causes are:
•
Dirty optical connector(s).
•
Equipment fault(s) in the upstream station.
Check upstream external cabling or equipment.