17.4.11 Pulse Count Control Area

It is used to change the input pulse when setting the pulse input to the high-speed pulse.
Offset
Bank
Name
address
Pulse count
240H
enable flag
00H
Pulse count
241H
value change
request flag
Pulse count
248H
change value of
249H
axis 1
Pulse count
24AH
change value of
24BH
axis 2
Pulse count
24CH
change value of
24DH
axis 3
Pulse count
24EH
change value of
24FH
axis 4
17-22
Descriptions
When the corresponding bit to each axis turns to 0, the count of pulse
input will start.
This flag is available only when setting the pulse input purpose to "High-
speed counter".
When the corresponding bit to each axis changes to 1 from 0, the pulse
input will be changed to the pulse count change value that the pulse input
count value has been set.
This flag is an edge trigger. Always chang e this flag to 1 from 0 before
change.
Set the pulse count value to be changed.