Table of Contents
Safety Precautions
3
Safe Installation
4
Safe Wiring
4
Safe Operation
5
Maintenance, Inspection and Part Replacement
7
Others
8
General Precautions
8
Warning Lable on Inverter
8
Table of Contents
9
Points for Handling
10
Special Precautions 9
11
Space Around the Inverter - Diagram
13
The Ambient Temperature
13
Avoid Installing the Inverter in the Following Locations...
13
Install the Inverter Vertically
13
Installation
13
Outline Dimensions
14
Parts Identification 13
15
Explanation of Inside of Terminal Cover
16
Opening and Closing Terminal Cover
16
Explanation of Operation Panel
17
Handling for the Displays of Output Current, Output Voltage and Internal DC Voltage
17
Precautions on Wiring
18
Wiring (Main Circuit) 16
18
Precautions for Using Regenerative Brakes
19
Connected Device, Wire Size and Main Circuit Terminal Tightening Torque
19
Wiring (Main Circuit Terminal)
19
Control Circuit Wiring
20
Wiring (Control Circuit Terminal)
20
Wiring (Output Terminals)
20
Relay Output Contact Specifications
20
Wiring ( Communication Terminals)
21
Terminals to Connect Personal Computers and Plcs by the RS485 Communication
21
Electric Cable Size and Control Circuit Terminal Tightening Torque
21
Wiring Method
21
Explanation of Control Circuit Terminals
22
Precautions on Wiring (2)
23
Judging the Pulse Signals of Phase a and B, and Forward/Reverse Directions
24
Operation (Basic Operation)
25
Setting the Frequency and Forward/Reverse Run Function with the Operation Panel
27
Combination of "Mop Function", "Rotation Direction Setting Mode" and Forward/Reverse Run Function
27
Operating with the Operation Panel -1 (Factory Setting State)
28
Example for Rotating in Forward Direction at Operating Frequency 5Hz
28
Example for Rotating in Forward Direction at Operating Frequency 10Hz
28
Changing the Frequency with the and Buttons During Operation (MOP Function)
28
Example to Change to Forward Rotation During Reverse Rotation
29
Stopping Operation
29
Operating with the Operation Panel - 2
30
Example to Change from Forward Run to Reverse Run During Operation
30
Canceling the Rotation Direction Setting
30
Rotation Direction Setting Mode, Control State Monitor Mode
31
Output Frequency Current Display Mode
31
Frequency Setting Monitor Mode
31
Function of each Modes 29
31
Custom Mode
32
Function Setting Mode
32
Function Setting Mode for Door Control
32
Control State Monitor
33
Output Current (N02), Output Voltage (N03), Internal DC Voltage (N04)
33
Detection Frequency (N06)
33
Door Position Area (N07)
34
Door Position (N08)
34
OPEN Arrival Position Data (N09)
34
No. of Door Switching (N10)
34
N16: Input Signal
35
N17: Output Signal
35
Setting and Changing Function 34
36
Setting Example: to Change Torque Boost Level from 10(%) to 5(%)
37
P Region Parameters: P01 to P81
38
Functional Descriptions (Parameter Table) 36
38
D Region Parameters : D01 to D65
41
1St Acceleration Time (Parameter P01)
43
1St Deceleration Time (Parameter P02)
43
V/F Pattern (Parameter P03)
43
Functional Descriptions (by Parameters) 41
43
Parameter P06: Setting of Electronic Thermal Function Details
44
Torque Boost Level (Parameter P05)
44
Electronic Thermal Function Select and Setting of Thermal Relay Current (Parameter P06, P07)
44
V/F Curve (Parameter P04)
44
Operation Command Select (Parameter P08)
45
Panel Reset Function
45
Panel STOP Function
45
Precautions on Operation Control with Control Terminal (External Control)
46
Frequency Setting Siagnal (Parameter P09)
47
Operation Mode of Door Control
47
Acceleration/Deceleration Time
47
Door Control Encoder Method
47
Max. Output Frequency and Base Frequency (Parameter P14 and P15)
48
Stop Frequency (Parameter P11)
48
DC Brake Time and DC Brake Level (Parameter P12 and P13)
48
Stop Mode (Parameter P10)
48
Overcurrent Stall Prevention Function (Parameter P16)
49
Overvoltage Stall Prevention Function (Parameter P17)
49
Skip Frequencies 1 to 3 (Parameter P18 and P20) and Skip Frequency Band Width (Parameter P21)
49
Current Limit Function (Parameter P22)
50
Start Mode (Parameter P23)
50
When Power Is Turned on with Run Signal on
51
When Run Signal Is Turned on after Power Is Turned on
51
Ride-Through Restart (Parameter P24)
52
When Voltage Drop Time Is more than 15Ms but Less than 100Ms
52
Retry Function and Retry Time (Parameter P26 and P27)
53
Wait Time (Parameter P25)
53
Monitor Select and Line Speed Multiplier (Parameter P30 and P31)
54
Parameter P26: Retry Selection Setting
54
Lower and Upper Frequency Clamp (Parameter P28 and P29)
54
Parameter P27: Retry Times Setting
54
Max. Output Voltage (Parameter P32)
55
OSC Level (Parameter P33)
55
Carrier Frequency (Parameter P34)
55
Communication Parameter (Parameter P35 to P40)
56
P Region Password (Parameter 41)
56
Procedures for Changing Parameter Data after Setting Password
56
Setting Method
57
Input Signal Logic Setting (Parameter P43)
57
Setting Data Clear (Parameter P42)
57
Setting Value
57
Safety Sensor Response Time (Parameter P44)
58
Arrival Signal Response Time (Parameter P45)
58
Encoder Fault Detect Time (Parameter P46)
58
Arrival SW Fault Detect Time (Parameter P47)
59
RY 1, 2, 3 Function Select (Parameter P48,49 and 50)
59
No. of Motor Poles and Encoder Constant (Parameter P51 to P52)
60
Detection Frequency
60
Overload Detection Frequency 1, 2 (Parameter P59 and P60)
61
Overload Detection Current 1, 2 (Parameter P61 and P62)
61
Overload Detection Judgment Time (Parameter P63)
61
Obstacle Detection Judgment Time (Parameter P67)
62
Obstacle Judgment Frequency Ratio (Low and High Speed) (Parameter P64 and P65)
62
Sandwich Judgment Change Frequency (Parameter P66)
62
Forced on Operation Judgment Time (Parameter P69)
63
Fault on Operation Forced Operation Time (Parameter P70)
63
Start Confirmation Time (Parameter P68)
63
Fault on Operation Open Arrival Hold Time (Parameter P71)
64
Repeat Open Arrival Hold Time (Parameter P72)
64
Repeat Close Arrival Hold Time (Parameter P73)
64
S-Shaped Acceleration/Deceleration Function (Parameter P74)
64
Stop Select in Open/Close Operation (Parameter P75)
65
Open Arrival Signal Select (Parameter P76)
65
Slip Arrival Judgment Frequency (Parameter P77)
65
Slip Arrival Judgment Time (Parameter P78), Slip Open Arrival Substitute Select (Parameter P79)
65
Parameter P79: Setting of Slip OPEN Arrival Substitute Select
66
Parameter P76: Setting of no Arrival Signal Select
66
Parameter P78: Slip Arrival Judgment Time Setting
66
Parameter P77: Slip Arrival Judgment Frequency Setting
66
Parameter P80: Safety Sensor Function Select
67
About Fault CLOSE Operation
67
Parameter P81: Forced OPEN Operation Judgment Time in Fault CLOSE Operation
68
Setting Value of Door Width (Parameter D01)
68
Arrival Position and Speed Change Position (Parameter D02 to D13)
69
Setting Change of OPEN/CLOSE Arrival Position (Parameter D02 and D08)
69
Arrival Hold Frequency (Parameter D14 and D21)
69
Acceleration and Deceleration Time (D28 to D39)
69
OPEN Operation in Encoder Mode
70
CLOSE Operation in Encoder Mode
70
Fault CLOSE Operation Speed Curve in Encoder Mode
71
OPEN Operation in SW Mode
72
CLOSE Operation in SW Mode
72
Fault CLOSE Operation Speed Curve in SW Mode
73
Operation Frequency When Power Supply Is Turned on (Parameter D51)
74
Door Width Measurement Frequency (Parameter D52)
74
D Region Password (Parameter D53)
74
Fault CLOSE Operation Frequency (Parameter D54 D59)
75
Fault CLOSE Operation Acceleration/Deceleration Time (Parameter D60 D65)
75
Operation Procedure of Custom Mode 74
76
Initial Setting Value of Self-Defining Mode and Initialization of Assignment Function
77
Supplementary Explanation of Door Width Measurement
78
Supplementary Explanation of Obstacle Detection Function of the Door
79
Four Major Reasons for Obstacle Detection
79
Operation Explanation of Obstacle Detection
79
Supplementary Explanation of Communication Function
80
About Communication Protocol
80
Send/Receive Changeover Wait Time
80
Processing Time on Inverter
80
Communication Function
81
Display Data and Transmission Data
82
Fault Details Monitor (DT 140 to 143)
82
Operation Status Monitor (R146)
83
Output Terminal State Monitor (R145)
83
Input Terminal State Monitor (R144)
83
Operation Control Status Monitor (R147)
84
Frequency Setting (DT 237 and 238)
84
Operation Control Setting (R250)
84
Fault Reset Command (DT253), Emergency Stop Command (DT255)
84
Error Codes in Communication
85
Parameter Setting Table
86
Details and Remedies for Fault Trips
91
Fault Trip Memory
91
Resetting Fault Trips
92
The Motor Does Not Rotate (When Fault Display Is Lit)
93
The Motor Does Not Rotate (When Fault Display Is Not Lit)
93
Troubleshooting
93
MCCB Trips
94
Motor Has over Temperature
94
Communication Is Not Available
94
Precautions for Inspections
95
Inspection Items
95
Parts Replacement
95
Maintenance and Inspection 93
95
Maintenance and Inspection Table
96
Specifications 95
97
Precautions on European Standard Directives
100
Conditions of CE Marking
100
Record of Changes
103
Advertisement
Advertisement
Related Products
Panasonic AFPE224302
Panasonic AFPX-C30R
Panasonic AFPX-C60T
Panasonic AFP7HSC2T
Panasonic AFP7FCA21
Panasonic AG-A800
Panasonic AW-RP60GJS
Panasonic AF7CPS Series
Panasonic AW-RP615AN
Panasonic AFP7Y16P
Panasonic Categories
Camcorder
Air Conditioner
TV
Digital Camera
Cordless Telephone
More Panasonic Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL