5. Remove the transfer belt unit.
6. Check or replace the transfer belt unit
and refit all the removed parts.
*: When refitting the transfer belt unit,
observe the precautions in the follow-
ing:
Insert the protrusion at the bottom of
the transfer belt unit into the square
hole on the conveying base.
7. When replacing the new transfer belt
unit, proceed as follows:
1) Performs maintenance mode U127
(clearing the transfer counter) (see
page 1-3-74).
2)Performs maintenance mode U464
(Calibration) (see page 1-3-154).
3)Performs maintenance mode U410
(Adjusting the halftone automatically)
(see page 1-3-138).
Protrusion
Tension
spring
Conveying base
Figure 1-5-62
1-5-36
2LL/2LJ/2LH
Transfer belt unit
Square
hole
Tension
spring

Hide quick links: