Kyocera TASKalfa 4500i Service Manual page 345

Hide thumbs Also See for TASKalfa 4500i:
Table of Contents

Advertisement

Code
Contents
6910
Engine software ready error
The device won't engage in
ready state in 60 minutes after
warming-up has began.
6940
Heater fan motor error
When the heater fan motor is
driven, the alarm signal is
detected for 5 s continuously.
7001
Toner motor error
During the toner motor is
driven, an event in which a
locking was detected for 5
times in 200 ms intervals has
occurred in 30 sets.
7101
Toner sensor error
Sensor output value of 60 or
less or 944 or more continued
for 3 s.
7200
Broken outer temperature
sensor wire
The sensor input sampling is
greater than 230.
Causes
Defective engine
Install the engine software.
software.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-47).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Heater fan motor and feed PWB 1 (YC11)
Feed PWB 1 (YC2) and engine PWB (YC5)
Defective heater
Replace the heater fan motor.
fan motor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-47).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Toner motor and engine PWB (YC27)
Defective toner
Replace the toner motor.
motor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-47).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Toner sensor and front PWB (YC7)
Front PWB (YC2) and engine PWB (YC8)
Defective toner
Replace developer unit (see page 1-5-28).
sensor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-47).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Outer temperature sensor and front PWB
(YC8)
Front PWB (YC2) and engine PWB (YC8)
Defective outer
Replace outer temperature sensor.
temperature sen-
sor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-47).
1-4-41
2LL/2LJ/2LH-2
Check procedures/
corrective measures

Hide quick links: