GPI Output Settings

Configure the trigger type and other settings for each GPI
output.

Configuring GPI Outputs

1
In the Engineering Setup >DCU >GPI Output Assign
menu (7354), select the target GPI output to set.
2
In the <Trigger Type> group, select the trigger
polarity.
(Rising Edge): Trigger causes the relay to open
or the output to go high level, and holds this state
for the pulse width duration.
(Falling Edge): Trigger causes the relay to close
or the output to go low level, and holds this state
for the pulse width duration.
(Any Edge): When a trigger occurs, the relay
opens/closes or the output goes high/low level,
switching state.
Status: The relay opens/closes or the output goes
high/low level in response to the status.
No Operation: The trigger has no effect on the relay
state or the output level.
3
Set the pulse width and timing.
No.
Parameter Adjustment
3
Pulse
Pulse width
Width
4
Timing
Output timing
a) 1: Field 1, 2: Field 2, 3: Any
Note
When "Any Edge" is selected as the trigger type, only
the [Timing] parameter is available. When "Status" is
selected as the trigger type, there are no parameter
settings.
4
In the <Source Device> group, select the control panel
to handle the GPI output.
PNL1: ID1 control panel
PNL2: ID2 control panel
PNL3: ID3 control panel
When the action set in step 5 is executed on the control
panel selected in this step, GPI output occurs. It is also
possible to output error information.
5
6
Trigger type and actions list
• When the trigger type is other than "Status"
• When the trigger type is "Status"
1) M/E-x: where x is the M/E number (1 to 5)
Testing trigger output
In the Engineering Setup >DCU >GPI Output Assign
menu (7354), press [Test Fire].
This outputs a trigger from the selected output port.
Note
This is no output when the trigger type is "Status."
a)
465
Select the action to set.
No.
Parameter Adjustment
2
Action
Action selection
5
Reg No
Register number
5
GPI No
GPI number
Press [Action Set].
M/E-x Keyx SS ? Recall, P/P DSKx SS ? Recall, No
Action
M/E-x Keyx SS ? Recall, P/P DSKx SS ? Recall, M/E-x
Keyx On, P/P DSKx On, Error Make, Error Break, Keep
Make, Keep Break, Device Recording, No Action
Keyx: where x is the key number (1 to 8)
DSKx: where x is the DSK number (1 to 8)