Sony MVS-8000X User Manual page 426

Multi format switcher system with icp-x7000 integrated control panel.
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

Command name
Pre Macro
Post Macro
Macro Take
Macro Cancel
Macro Auto Ins
Macro AT with Rate
Macro AT with A/B Bus
Macro TL with Region
DME Override
DME Graphic
FTB
SWR1 LAN Status
SWR2 LAN Status
a) The safe title enable/disable commands display the name of the signal
assigned to the output.
b) Control LAN status only.
Setting names to display in memory recall
buttons
You can set the display of names on buttons when menu
shortcuts or utility commands are assigned to the memory
recall buttons.
Note
When a macro register is assigned, the names specified in
the Macro menu are displayed on the memory recall
buttons. When a shotbox register is assigned, the names
specified in the Shotbox menu are displayed on the
memory recall buttons.
Function
Sets macro attachment in pre macro
mode.
Sets macro attachment in post macro
mode.
Macro execution
Macro cancel
Macro auto insert mode enable/disable Enabled
Mode enable/disable for storing
transition rate when registering an
auto transition macro event
Mode enable/disable for storing A/B
bus cross-points when registering an
auto transition macro event on the
transition control block
Mode enable disable for saving target
regions when registering a timeline
macro event
DME override enable/disable
DME graphics enable/disable
(applies to graphics for channel
selected in device control block)
Fade-to-black execution
SWR1 communications status
SWR2 communications status
1
2
3
Setting the transition rate target to display
on memory recall buttons
This sets the memory recall button assignments in
transition rate display mode.
1
424
Button state
Lit orange
Can be set only while
pressed (lit)
Can be set only while
pressed (lit)
Lit light purple during
execution
Lit purple during
pause
Lit only at the instant
the button is pressed
Enabled
Enabled
Enabled
Enabled
Enabled
Lit light purple during
execution
Lit red when
execution completed
(image in black state)
b)
Communication
s disconnected
b)
Communication
s disconnected
In the Engineering Setup >Panel >Prefs/Utility
>Utility Module Assign menu (7324.1), select the
target button to set.
Press [Name].
Enter a name of up to 8 characters in the keyboard
window, and press [Enter].
In the Engineering Setup >Panel >Prefs/Utility
>Utility Module Assign menu (7324.1), press [Trans
Rate Mode Assign].
The Trans Rate Mode Assign menu (7324.3) appears.
Lit dark blue
Function assigned
Function assigned
Function assigned
(gray characters
displayed on black
background)
Function assigned
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Function assigned (lit
purple)
During
communicatio
n
During
communicatio
n

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents