Multi Program 2 Mode Settings (Basic Operation) - Sony MVS-8000X User Manual

Multi format switcher system with icp-x7000 integrated control panel.
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

Multi Program 2 Mode Settings
(Basic Operation)
Entering the software install key (first time
only)
After installing the BZS-8200X or the BZS-7200X Multi
Program 2 software in the switcher, carry out the following
procedure.
1
In the status area of the Engineering Setup >System
>Install/Unit Config menu (7316), select the switcher
(SWRx) and press [License].
The License menu (7316.6) appears.
2
Enter the software install key.
For details, see "Configuring Settings to Use the
Software" (page 400).
3
Turn the switcher off and then on again.
Setting the operating mode for a switcher
bank
Set Multi Program 2 mode for each switcher bank.
1
Open the Engineering Setup >Switcher >Config menu
(7331).
2
In the status area, select the target switcher bank.
3
In the <M/E Config> group, select [Multi Program2].
4
Repeat steps 2 and 3 as required, to set the operation
mode for all target switcher banks.
Assigning output signals for Multi
Program 2 mode
To assign a signal to an output
Use the Engineering Setup >Switcher >Config >M/E
Output Assign menu (7331.1).
In Multi Program 2 mode, OUT1 is fixed to PGM1 (main
program), OUT6 is fixed to PGM2 (sub program), and the
OUT2 to OUT5 signals can be assigned signals selected
from among the following.
PGM1, PGM2, PGM3, PGM4, PVW1, PVW2,
K-PVW1, K-PVW2, CLEAN, SUB CLEAN
Note
Either the main and sub use a maximum of four of the six
outputs (OUT1 to OUT6). The outputs can be used within
the following limits.
• OUT1, OUT2: main only
• OUT3, OUT4: can be used for either main or sub
• OUT5, OUT6: sub only
For details, see "Assigning the output of each bank in
multi-program mode" (page 434).
To set the background and key configuration
Use the Engineering Setup >Switcher >Config >PGM
Config menu (7331.2).
The differences from operation in standard mode are as
follows.
Background configuration: Consists of the following
combinations.
• Main bank: Clean, Bkgd A, Bkgd B
• Sub bank: Sub Clean, Utility 2, Utility 3
Key configuration: Key1 can be enabled only when the
background is Clean, Bkgd A, or Bkgd B.
For details, see "Setting the output configuration for each
bank" (page 435).
To set the key preview configuration
Use the Engineering Setup >Switcher >Config >K-PVW
Config menu (7331.3).
The differences from operation in standard mode are as
follows.
Background configuration: Clean or Sub Clean
Key configuration: Key1 can be set to [On] or [Link] only
when the background is Clean.
For details, see "Setting the key preview configuration"
(page 435).
To assign sub bank outputs to output connectors
Use the Engineering Setup >Switcher >Output >Output
Assign menu (7333.1).
You can assign a sub bank output signal to a switcher
output connector number.
For details, see "Assigning Output Signals" (page 443).
Assigning main/sub to switcher banks
For each switcher bank for which Multi Program 2 mode
is selected, set whether the bank is dedicated main (Main),
dedicated sub (Sub), or shared main and sub (Main&Sub).
To assign main and sub to a single switcher bank
1
In the status area of the Engineering Setup >Panel
>Config >MP2 Main/Sub Assign menu (7321.11),
select the switcher bank.
2
In the <Main/Sub Assign> group, select [Main&Sub].