Sony MVS-8000X User Manual page 455

Multi format switcher system with icp-x7000 integrated control panel.
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

No.
Parameter Adjustment
1
Port
Port selection
2
No
Selection of number for action to be
assigned
3
In the <Trigger Type> group, select the trigger
polarity.
(Rising Edge): Trigger on the rising edge of the
input pulse.
(Falling Edge): Trigger on the falling edge of
the input pulse.
(Any Edge): Trigger on an inversion of the
input pulse.
(Level): Trigger when the level of the input
pulse is low or high.
No Operation: Not triggered by an input pulse.
4
In the <Target> group, select the target bank to set.
M/E-1 to M/E-5, P/P: Set the actions relating to each
bank.
Common/Setup: Set an action relating to all banks, or
an action relating to setup.
5
Select the action to set.
No.
Parameter Adjustment
3
Action
Action selection
4
Reg No
Register number
6
Press [Action Set].
Trigger type and actions list
• When the trigger type is other than "Level"
When Target is M/E-x: Cut, Auto Trans, Keyx Cut,
Keyx Auto Trans, SS ? Recall, Keyx SS ? Recall, Effect
? Recall, Effect ? Recall & Run, KF Run, KF Stop, KF
Rewind, KF Rev Run, No Action
When Target is P/P: Cut, Auto Trans, DSKx Cut, DSKx
Auto Trans, FTB Cut, FTB Auto Trans, SS ? Recall,
DSKx SS ? Recall, Effect ? Recall, Effect ? Recall &
Run, KF Run, KF Stop, KF Rewind, KF Rev Run, No
Action
When Target is Common/Setup: FM Src1 Field Freeze,
FM Src1 Frame Freeze, FM Src2 Field Freeze, FM Src2
Frame Freeze, FM Src1 Freeze Off, FM Src2 Freeze Off,
FM Src1 Clip Record, FM Src1 Clip Stop, FM Src2 Clip
Record, FM Src2 Clip Stop, FM1 to FM8 Clip Cueup,
FM1 to FM8 Clip Play, FM1 to FM8 Clip Stop, User1 to
8 SS ? Recall, User1 to 8 EFF ? Recall, User1 to 8 EFF
? Recall & Run, User1 to 8 KF Run, User1 to 8 KF Stop,
User1 to 8 KF Rewind, User1 to 8 KF Reverse Run, No
Action
• When the trigger type is "Level"
When Target is M/E-x or P/P: Aspect, Bkgd A Side
Flags, Bkgd B Side Flags, No Action
1)
453
When Target is Common/Setup: Format, Aspect, Level
Enable, No Action
1) M/E-x: where x is the M/E number (1 to 5)
Keyx: where x is the key number (1 to 8)
DSKx: where x is the DSK number (1 to 8)
Notes
• "Level Enable" is a function that determines whether
GPI inputs are enabled ("Enable") or disabled
("Disable") for the "Aspect" and "Format" actions that
can be used when the trigger type is "Level". When
"Level Enable" is used, if the input is "Disable" then it
is not possible to switch "Aspect" or "Format" by GPI
input.
If a GPI action is triggered just as system power is turned
off, such as by switching "Aspect" or "Format," the
action may be executed immediately before the power
goes off and the power may go off before the action is
completed. This may corrupt the setup. It is therefore
recommended to use "Level Enable" to avoid such a
situation.
• When using the format converter with "Action" set to
"Format," you can set the conversion format of the
format converter for "FC Input 1-4," "FC Input 5-8,"
"FC Input 9-12" (MVS-8000X only), "FC Input 13-16"
(MVS-8000X only), "FC Output 1-2," and "FC Output
3-4."
Configuring level settings
Configure the settings for low level and high level when
the trigger type is set to "Level."
1
In the Engineering Setup >Switcher >Device Interface
>GPI Input menu (7337.2), select an action and press
[H/L Set].
The H/L Set menu (7337.3) appears.
2
Select the setting.
No.
Parameter Adjustment
2
Item No
Selection of setting for action
3
To trigger an action when the input is high level or low
level, press [H Set] or [L Set], respectively.
If the action is "Format," press [H Set] or [L Set] in the
<SWR> group.
Notes
• When the action is "Format," these settings conflict
with the current settings, but after making the
settings, agreement is restored after a pulse change
or power off/on.