Settings Relating To Operation; Setting The On-Air Tally; Setting The Transition Rate Display Mode; Setting The Transition Indicator Display In Non-Sync State - Sony MVS-8000X User Manual

Multi format switcher system with icp-x7000 integrated control panel.
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

Settings Relating to
Operation

Setting the On-Air Tally

This sets the high tally state reflected on the control panel.
1
In the Engineering Setup >Panel >Operation menu
(7326), press [Button Tally].
The Button Tally menu (7326.9) appears.
2
In the <Tally Type> group, select one of the following.
[R1] to [R8]: Reflect the tally state of the tally groups
1 to 8.
Independ: Reflect the tally state of the switcher only.
3
Press [Execute].
Setting the Transition Rate Display
Mode
This sets the transition rate display mode to the number of
frames or to a timecode.
In the <Trans Rate Display> group of the Engineering
Setup >Panel >Operation menu (7326), select one of the
following.
Frame: Display as number of frames.
Timecode: Display as timecode (SS:FF).
Setting the Transition Indicator
Display in Non-Sync State
In the <Non Sync Fader Indicator> group of the
Engineering Setup >Panel >Operation menu (7326), select
one of the following.
Normal: The transition indicator is lit when in non-sync
state.
Blink: The transition indicator is blinking when in non-
sync state.

Configuring Settings Relating to

Effects

Setting functions used in keyframe effect
operations
In the Engineering Setup >Panel >Operation menu (7326),
press [Effect Mode] to open the Effect Mode menu
(7326.2).
Configure each function, as required.
Setting the first keyframe state when recalling an
effect
In the <Recall Mode> group, select one of the following.
Recall: The first keyframe is not reproduced.
Recall&Rewind: The first keyframe is reproduced.
Disabling the [EDIT ENBL] button when recalling
an effect
Press [Edit Enable Auto Off], turning it on.
If an effect is recalled when the [EDIT ENBL] button is lit,
the [EDIT ENBL] button is automatically disabled.
Inserting the first keyframe automatically
Press [1st KF Auto Insert], turning it on.
When an empty register is recalled, the state at that point is
automatically inserted as the first keyframe.
Setting auto save for an effect
Press [Effect Auto Save], turning it on.
When an effect is recalled after effect editing, the edited
effect is automatically saved.
Setting the default value of keyframe duration
Press [Default KF Duration], then enter the default value
using the numeric keypad window.
Setting the first keyframe when rewind is
executed
For P-Bus, GPI, and DDR/VTR timeline operations, you
can set to execute the first keyframe when rewind is
executed.
Note
When enabled and an effect is executed by pressing the
[RUN] button, the first keyframe action is not executed.
In the <Rewind&1st KF> group of the Engineering Setup
>Panel >Operation >Effect Mode menu (7326.2), select
the target to set.
GPI: GPI timeline
P-Bus: P-Bus timeline
DDR/VTR: VTR/disk recorder/Extended VTR timeline
Macro: Macro timeline
427