No.
Parameter Adjustment
3
Command
Utility command selection
GPI No
GPI number
a)
4
a) SWR GPI Test Fire and DCU GPI Test Fire commands only
When [Macro Recall] is selected: Select the macro
register to assign.
No.
Parameter Adjustment
3
Macro
Macro register selection
When [Shotbox Recall] is selected: Select the
shotbox register to assign.
No.
Parameter Adjustment
3
Shotbox
Shotbox register selection
List of utility commands and memory recall button states
The following table lists the utility commands that can be
assigned to memory recall buttons.
Command name
SWR Remote1 Enbl
|
SWR Remote4 Enbl
DME1 Editor Port Enbl
DME2 Editor Port Enbl
DME3 Editor Port Enbl
DME4 Editor Port Enbl
a)
MEx PGM1 ST
|
a)
MEx PGM4 ST
a)
MEx PVW ST
a)
MEx Clean ST
a)
MEx K-PVW ST
a)
PP PGM1 ST
|
a)
PP PGM4 ST
a)
PP PVW ST
a)
PP Clean ST
a)
PP K-PVW ST
a)
DME Mon Video ST
5
To release the assignment
Select the target button to release, then press [Clear].
To display register names in the Utility Command
field
When [Macro Recall] or [Shotbox Recall] is selected in
step 3, you can select whether to display register names in
the Utility Command field.
To enable display, press [Reg Name Display], turning it
on.
Function
Switcher REMOTE1 enable/disable
|
Switcher REMOTE4 enable/disable
DME1 editor port enable/disable
DME2 editor port enable/disable
DME3 editor port enable/disable
DME4 editor port enable/disable
M/E-x PGM output safe title enable/
disable
x = 1 to 5
M/E-x preview output safe title enable/
disable
x = 1 to 5
M/E-x clean output safe title enable/
disable
x = 1 to 5
M/E-x key preview output safe title
enable/disable
x = 1 to 5
P/P PGM output safe title enable/
disable
P/P preview output safe title enable/
disable
P/P clean output safe title enable/
disable
P/P key preview output safe title
enable/disable
DME Monitor Video output safe title
enable/disable
422
Press [Action Set].
When [Menu Shortcut] is selected in step 3, it is not
necessary to press [Action Set].
Button state
Lit orange
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Lit dark blue
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled