Control Of Gpi Devices; Creating And Editing The Gpi Timeline - Sony MVS-8000X User Manual

Multi format switcher system with icp-x7000 integrated control panel.
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

The control block switches to effect operation mode,
and the [EFF] button and [RCALL] button light
amber.
2
Press the [P-BUS] button to select the P-Bus region.
3
Enter the register number (1 to 250) to be recalled
using the numeric keypad buttons.
4
Press the [ENTER] button.

Control of GPI Devices

In this system, you can control GPI devices through the
GPI output port of an SIU.
GPI timeline
For a keyframe effect controlled from the control panel,
the GPI timeline allows you to set an action (setting a
trigger output from a particular GPI output port) at a
keyframe point on the GPI timeline. At any keyframe
point, you can make a maximum of eight GPI output port
settings.
GPI timeline actions
The actions that can be used on the GPI timeline are as
follows.
• SIU GPI output port
Creating and Editing the GPI
Timeline
You can set GPI output ports to be registered at a keyframe
point, and create the GPI timeline.
For details about keyframe creation, see "Creating and
Editing Keyframes" (page 310).
For the GPI output settings (keyframe editing), use the
Device menu.
The data set in the Device menu is saved in a keyframe
effect register. When you recall the register and start
execution of the keyframe effect, and advance the effect to
the keyframe point for which the GPI output is set, a
trigger pulse is output to the external device from the
specified GPI output port.
GPI output port settings
Set the GPI output port number of the SIU which outputs
GPI pulses at a keyframe point on the GPI timeline.
1
Open the Device >GPI Timeline >GPI Timeline menu
(5311).
In the status area, two lists appear.
The left list shows the relation between ports 1 to 8 for
the GPI timeline and the trigger pulse output
destination ports. The content of this list is saved as
keyframe point data. The "GPI Port" list on the right,
select the GPI trigger pulse output destination.
2
Select the GPI timeline port.
286

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents