64 Chapter 4 SMP log error messages
Message
Closed telnet connection from <ip-address> user <user-name>
Severity
INFO
Description
This message is generated when a telnet connection to the switch terminates.
Synopsis
N/A
Action
N/A
Message
Connection lost to slot <value> ...
Severity
ERROR
Description
IPC connection between the CP card and a given I/O slot is lost.
Synopsis
N/A
Action
Reboot the switch and contact the customer support team if the problem persists.
Message
Connection not found for connection Id <value>
Severity
ERROR
Description
IPC connection between the CP card and I/O card cannot be found in software
database.
Synopsis
N/A
Action
This is caused by the IPC connection setup, or a corruption of the software data
structures.
Message
Consistency check failed for Bootp table syncing RED_BOOTP_INFO
Severity
ERROR
Description
This message indicates a consistency check for the bootp table failed.
Synopsis
N/A
Action
N/A
Message
cosLibInit: failed
Severity
ERROR
Description
This message specifies the CoS library initialization failed.
Synopsis
N/A
Action
Reboot the switch if you wish to use CoS functions.