202 Chapter 4 SMP log error messages
Message
traceDumpBkTr: failed to get CP slot number
Severity
ERROR
Description
This message is generated when the system fails to get the CP slot number when
sending trace info from the coprocessor.
Synopsis
N/A
Action
N/A
Message
traceStart: Cannot create CopTraceLockSemId semaphore
Severity
FATAL
Description
This message is generated when the system cannot create the semaphore.
Synopsis
N/A
Action
Reboot the switch and contact the customer service team if the problem persists.
Message
traceStart: malloc failed
Severity
FATAL
Description
This message is generated when the system runs out of memory.
Synopsis
N/A
Action
Reboot the switch and contact the customer service team if the problem persists.
Message
trBmErrorHandler: resetting slot <value>
Severity
ERROR
Description
This message is generated when there are buffer management errors on a given
slot and the card is being reset to recover from the error condition.
Synopsis
N/A
Action
N/A
Message
trBmErrorHandler: send reset request to secondary CP
Severity
ERROR
Description
This message is generated when there are buffer management errors on the
secondary CPU and a message is being sent asking it to reset itself.
Synopsis