Nortel 8300 Reference Manual page 173

Ethernet routing switch system messaging platform
Hide thumbs Also See for 8300:
Table of Contents

Advertisement

Message
rcIpAddStaticArp: arpadd failed for failed
Severity
ERROR
Description
This message is generated if the addition of a static ARP entry in the ARP table
failed.
Synopsis
Addition of static ARP table entry failed.
Action
Contact customer support for further troubleshooting.
Message
rcIpAddStaticArp: ipCircFromIFID failed
Severity
ERROR
Description
This message is generated when the circuit data is null for a given circuit ID.
Synopsis
Getting semaphore failed.
Action
Contact customer support for further troubleshooting.
Message
rcIpAddStaticArpByPort: found an arp while adding the entry
Severity
ERROR
Description
This message indicates that an existing ARP entry was discovered while trying to
add the static ARP entry with the same IP address.
Synopsis
N/A
Action
Contact the customer support team if the problem persists.
Message
rcIpAddStaticRoute: arpaddUnres returns NULL
Severity
FATAL
Description
This message is generated if system is not able to locate an entry in the
unresolved table.
Synopsis
Search failed.
Action
Contact customer service and have the following information available for further
analysis: system logs including any memory dumps, switch configuration, and
network topology.
Message
rcIpAddStaticRtsByArp: could not find the specified nexthop
Severity
ERROR
Description
This message is generated when an ECMP path index for a non-local static route
is not equal to its maximum value.
Synopsis
Value mismatch.
Action
Check the configuration for the maximum value of the ECMP path index.
Chapter 4 SMP log error messages 173