Message
Slot <value> Xbar has invalid Multicast Table. Failed to rewrite <value> times
Severity
ERROR
Description
This message is generated when the multicast table on the slave CPU crossbar is
corrupted and cannot be corrected.
Synopsis
N/A
Action
Re-insert or replace the card.
Message
Slot <value> Xbar has invalid Multicast Table. Failed to rewrite <value> times
Severity
FATAL
Description
This message is generated when the multicast table on Xbar on the master CPU
is corrupted and cannot be corrected.
Synopsis
N/A
Action
Re-insert or replace the card.
Message
Slot%d - card not init yet
Severity
ERROR
Description
This message is generated when card hardware has not yet been fully initialized
by the chassis.
Synopsis
Card not initialized.
Action
Contact customer support for further troubleshooting.
Message
Slot: <value> Current State: <value>
Severity
INFO
Description
This message is generated when a card is inserted from a slot in non-hidden
mode.
Synopsis
Slot and state for the previous log message.
Action
N/A
Message
Socket failed
Severity
INFO
Description
This message is generated when the system cannot create a new socket.
Synopsis
N/A
Action
Reboot the switch and contact the customer service team if the problem persists.
Chapter 4 SMP log error messages 193
System Messaging Platform Reference Guide