Message
aclHwBuildPceParamBlock(): AclId <value> ProfileId <value> NOT FOUND
<value>
Severity
ERROR
Description
The template is expected in the hardware, but is not found.
Synopsis
N/A
Action
Try removing or enabling filters on the port. Try to delete or create for the ACG
from the port. Check dump using aclDumpAclTbl() or aclDumpAceList().
Message
aclHwBuildPceParamBlock(): Pcl size <value> exceeding Max Pcl size <value>
for AclId <value>
Severity
ERROR
Description
Specified ACG required more than 128 filters in the hardware. This could result
from an attempt to use rules with conditional matching such as greater, less,
range, not-equal.
Synopsis
N/A
Action
Try to minimize the operators. If that does not help, remove some ACEs from the
ACLs.
Message
aclHwBuildPceParamBlock(): Profile is corrupted # of Match fields exceeding limit
per Pce <value>
Severity
WARNING
Description
The hardware cannot support more than 16 bytes for each ACL type. A missing or
incomplete consistency check or corruption can cause this.
Synopsis
N/A
Action
Try removing or enabling filters on the port. Try to delete or create the Acg from
the port. Check dump using aclDumpAclTbl() or aclDumpAceList().
Message
aclHwBuildPceParamBlock(): ProfileEntry's MatchInfo has unsupported field
<value> at index <value>
Severity
WARNING
Description
A rule in the ACL has a match field that could not be handled correctly.
Synopsis
N/A
Action
Try removing or enabling filters on the port. Try to delete or the ACG from the port.
Check dump using aclDumpAclTbl() or aclDumpAceList().