(such as images, text, recordings or pictures) and related licensed materials including all whole or partial copies. Nortel Networks grants you a license to use the Software only in the country where you acquired the Software. You obtain no rights other than those granted to you under this License Agreement. You are responsible for the selection of the Software and for the installation of, use of, and results obtained from the Software.
New York. International regulatory statements of conformity This is to certify that the Nortel Networks 8300 Series chassis and components installed within the chassis were evaluated to the international regulatory standards for electromagnetic compliance (EMC) and safety and were found to have met the requirements for the following international standards: •...
CE marking statement (Europe only) EN 55 022 statements This is to certify that the Nortel 8300 chassis and components installed within the chassis are shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC. Conformity is declared by the application of EN 55 022 Class A (CISPR 22).
Page 5
EN 60 950 statement This is to certify that the Nortel 8300 chassis and components installed within the chassis are in compliance with the requirements of EN 60 950 in accordance with the Low Voltage Directive. Additional national differences for all European Union countries have been evaluated for compliance.
Page 6
Exportador: Nortel Networks 4655 Great America Parkway Santa Clara, CA 95054 USA Importador: Nortel Networks de México, S.A. de C.V. Avenida Insurgentes Sur #1605 Piso 30, Oficina Col. San Jose Insurgentes Deleg-Benito Juarez México D.F. 03900 Tel: 52 5 480 2100 Fax: 52 5 480 2199 Embarcar a: 8301 •...
How to get help 15 Getting help from the Nortel web site 15 Getting help over the phone from a Nortel Solutions Center 15 Getting help from a specialist using an Express Routing Code 15 Getting help through a Nortel distributor or reseller 16...
Before you begin This guide is intended for qualified service personnel who need to install or replace Nortel Ethernet Routing Switch 8300 modules in the chassis. A qualified service person should have appropriate technical training and experience and be aware of the hazards involved in installing and replacing customer-replaceable units.
Getting help over the phone from a Nortel Solutions Center If you do not find the information you require on the Nortel Technical Support web site, and you have a Nortel support contract, you can also get help over the phone from a Nortel Solutions Center.
16 Preface Getting help through a Nortel distributor or reseller If you purchased a service contract for your Nortel product from a distributor or authorized reseller, contact the technical support staff for that distributor or reseller. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard...
"Cleaning fans in an 8306, 8310, 8006 or 8010 chassis" (page 18) Cleaning fans in an 8306, 8310, 8006 or 8010 chassis WARNING Nortel advises that the chassis be powered down while cleaning fans and vents. Do not run a system for more than five minutes without a operational fan tray.
Page 19
If the chassis is powered on, the fans start turning when the fan tray connectors are fully engaged. Installing a fan tray in an 8306, 8310, 8006 or 8010 Chassis Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
8306 Chassis. This fan tray contains six high-capacity fans and a control/monitor circuit board. The Ethernet Routing Switch 8006 and 8306 Chassis has a single fan tray that is installed on the right side of the chassis. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
8310 Chassis. This fan tray contains eight high-capacity fans and a control/monitor circuit board. The Ethernet Routing Switch 8010 and 8310 Chassis has two fan trays installed on the right side of the chassis. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
You can replace a fan tray in the 8306, 8310, 8006, or 8010 chassis with the power on or off. Fan tray LED on Switch Fabric Modules The following figure shows the location of the LEDs for the fans. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
(either Ethernet Routing Switch 8301AC or 8302AC power supplies). If they are not the same, all PoE (8348TX-PWR, 8348GTX-PWR) modules lose PoE. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
Page 24
Location of the LED on 8301AC, 8302AC and power supplies Verify that the power supply status LEDs and the fan LED on the switch fabric modules light green. Switch fabric module Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
Once a year, the slots and backplane must be cleaned using a vacuum or brushes. You want to carefully plan this activity so that traffic disruption is minimized. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
"Installing a module" (page 30) Static concerns The Nortel Ethernet Routing Switch 8300 Series modules are sensitive to static electricity. Static discharge from your clothing or other fixtures around you, even at levels that do not create a spark, can cause damage.
Always assume that fiber optic cables are connected to a light source. Removing a filler panel Nortel ships the Ethernet Routing Switch 8000 series chassis with a filler panel covering each empty module slot. On a 8006, 8010, 8306, or 8310 Chassis, the filler panel covers an empty module slot.
Pull the filler panel away from the slot. —End— Removing a module You can remove any Nortel Ethernet Routing Switch 8300 module from an operating switch chassis without turning off the chassis power. CAUTION Before you remove a switch fabric module, back up your configuration.
Page 29
Removing modules and cleaning slots and the backplane 29 CAUTION Do not operate the Nortel Ethernet Routing Switch 8300 Series with an empty module slot. If you need to replace a failed module and you do not yet have a replacement module, leave the failed module installed or install a filler...
—End— Installing a module You can install an Nortel Ethernet Routing Switch 8300 module with the power on or off. If you install a module in the same chassis slot where the same type of module was previously installed, the previous configuration is maintained for that module in that slot.
Page 31
Electrostatic discharge can damage hardware. Review the antistatic precautions on "Static concerns" (page 26). To install an Nortel Ethernet Routing Switch 8300 Series module: Step Action Locate the slot where you want to install the module. Remove the installed module or the filler panel.
Page 32
Securing the module in the chassis: 8006, 8010, 8306, and 8310 Chassis —End— After you install the modules, you can connect console equipment and network cables. For instructions, see Nortel Ethernet Routing Switch 8300 Installation — Modules (NN46200-305). Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard...
Figure 12 "monitor ports stats interface utilization command output" (page displays an example of output for the monitor ports stats interface utilization command. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
The total number of flow control packets transmitted by this interface. Graphing ethernet error statistics Use the Ethernet Errors tab to graph Ethernet error statistics. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
In particular, an instance of this object can represent a count of receive errors on a particular interface that are not otherwise counted. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
A yellow outline appears around the selected ports. From the Device Manager main menu, select Graph > Port. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
Select the statistic(s) you want to graph. In the Poll Interval box, select the polling interval. Click the Graph button (bar, pie, chart, line). —End— Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
Select the statistic(s) you want to graph. In the Poll Interval box, select the polling interval. Click a line, area, bar or pie chart button. —End— Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
The EAPOL Stats tab for graphing a single port or multiple ports appears. See "Graph Ports dialog box - EAPOL Stats tab" (page 57) "Graph Ports dialog box - EAPOL Stats tab" (page 57) Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
The VRRP Stats window for the selected interface appears. Highlight the numerical data to graph. Click either the line, area, bar, or pie, chart button. —End— Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
first. If the Ethernet Routing Switch 8300 has a real-time clock, the log file shows real time. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
The show logging config command displays the level of information being entered in the log. The level ranges from information (INFO), where all messages are entered, to FATAL, where only fatal errors are recorded. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
file, where the tail option was entered to display the most recent information first. If the Nortel Ethernet Routing Switch 8300 Series has a real-time clock, the log file shows real time. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard...
FATAL, where only fatal errors are recorded. The manufacturing (MFG) level is for manufacturing purposes only and not available for customer use. To display the level information, use the following command: Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
Adds the IP address of the host, to which the log file needs add-IP to be transferred. You can configure only a reachable remote host. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
If this option is set, the previously transferred log file is overwritten on the remote server. Nortel recommends that you not set this option. Shows the configured IP address and the file name for the info remote host.
Switch Fatal messages, and enable the sending of syslog messages. The example also uses the info command to display system log information for the specified host. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
You can enable the system log feature globally to send messages to up to 10 syslog hosts. By default, five hosts are supported. To enable the system log feature globally: Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
UNIX workstation concurrently handles messages received from applications running on the workstation, as well as messages received from Ethernet Routing Switch 8000 Series running in a network accessible to the workstation. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
For all Device Manager log dialog boxes, there is a clear button that clears the log. Managing Files During changes and monthly, Nortel recommends removing any old files after examining the directory and backing up current configurations. You can automate this process using scripts in a scripting language of your own choice.
Copying a runtime image from TFTP server to local PCMCIA: copy 192.168.249.10:p83a3000.img /pcmcia/p83a3000.img Copying a runtime image from PCMCIA to a local flash: copy /pcmcia/p83a3000.img /flash/p83a3000.img Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
/pcmcia/ repair command or the dos-format command. For example, to save a boot configuration file as a backup file, you use the following command: save bootconfig file boot.cfg backup2 Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
files, look on the PCMCIA card for files usually ending with a triple 0 (for example, /PCMCIA/a6d00005.000). You can also find a syslog or a sysHwLog depending on the fault. Nortel Ethernet Routing Switch 8300 Series Routine Maintenance NN46200-514 03.01 Standard 4.0 27 August 2007...
Sourced in Canada and the United States of America. The information in this document is subject to change without notice. Nortel Networks reserves the right to make changes in design or components as progress in engineering and manufacturing may warrant.