Parameter Setup
PrNo.
Title
0B
Setup of
*
absolute encoder
0C
Baud rate setup of
*
RS232
communication
0D
Baud rate setup of
*
RS485
communication
0E
Setup of front
*
panel lock
Parameters for Adjustment of Time Constants of Gains and Filters
PrNo.
Title
11
1st gain of
velocity loop
12
1st time constant
of velocity loop
integration
13
1st filter of
speed detection
14
1st time constant of
torque filter
146
Setup
range
0 to 2
You can set up the using method of 17-bit absolute encoder.
<1>
Setup value
0
Use as an absolute encoder.
<1>
Use as an incremental encoder.
2
Use as an absolute encoder, but ignore the multi-turn counter over.
<Caution>
This parameter will be invalidated when 5-wire, 2500P/r incremental encoder is used.
0 to 5
You can set up the communication speed of RS232.
<2>
Setup value
0
1
<2>
0 to 5
You can set up the communication speed of RS485.
<2>
Setup value
0
1
<2>
You can limit the operation of the front panel to the
0 to 1
monitor mode only.
<0>
You can prevent such a misoperation as unexpec-
ted parameter change.
<Note>
You can still change parameters via communication even though this setup is 1.
To return this parameter to 0, use the console or the "PANATERM
Setup
Unit
range
1 to 3500
Hz
You can determine the response of the velocity loop.
A to C-frame:<35>*
In order to increase the response of overall servo system by setting high
D to F-frame:<18>*
position loop gain, you need higher setup of this velocity loop gain as well.
However, too high setup may cause oscillation.
<Caution>
When the inertia ratio of Pr20 is set correctly, the setup unit of Pr11
becomes (Hz).
1 to 1000
ms
You can set up the integration time constant of velocity loop.
A to C-frame:<16>*
Smaller the setup, faster you can dog-in deviation at stall to 0.
D to F-frame:<31>*
The integration will be maintained by setting to "999".
The integration effect will be lost by setting to "1000".
You can set up the time constant of the low pass filter (LPF) after the
0 to 5
speed detection, in 6 steps.
<0>*
Higher the setup, larger the time constant you can obtain so that you can
decrease the motor noise, however, response becomes slow. Use with a
default value of 0 in normal operation.
0 to 2500
0.01ms
You can set up the time constant of the 1st delay filter inserted in the
A to C-frame:<65>*
torque command portion. You might expect suppression of oscillation
D to F-frame:<126>*
caused by distortion resonance.
Function/Content
Content
Baud rate
Setup value
2400bps
3
4800bps
4
9600bps
5
Baud rate
Setup value
2400bps
3
4800bps
4
9600bps
5
Function/Content
Standard default : < >
• Error of baud rate is ±0.5%.
Baud rate
19200bps
38400bps
57600bps
• Error of baud rate is ±0.5%.
Baud rate
19200bps
38400bps
57600bps
Setup value
Content
<0>
Valid to all
1
Monitor mode only
®
".
Standard default : < >