Panasonic minas a4 series Instruction Manual page 169

Ac servo motor and driver
Hide thumbs Also See for minas a4 series:
Table of Contents

Advertisement

Title of signal Pin No.
Torque command
16
input
*Function becomes valid when the control mode with underline (
is selected while the switching mode is used in the control mode in table.
<Remark>
Do not apply more than ±10V to analog command inputs of SPR/TRQR/SPL
Do not apply more than ±10V to analog command input of TRQR.
[Connection and Setup of Torque Control Mode]
Symbol
TRQR
• Function varies depending on Pr02 (Control mode setup).
Pr02
Control mode
2
Torque Control
4
Position/Torque
Velocity/
5
Torque
Position/Torque
4
Velocity/Torque
5
Other
Other
control mode
• Resolution of A/D converter used in this input is 16 bit
(including 1 bit for sign).
± 511 [LSB] = ± 11.9[V], 1 [LSB]
Function
Function
• Function varies depending on Pr5B (Selection of
torque command)
Pr5B
Content
This input becomes invalid.
0
• Torque command input (TRQR) will be
selected.
• Set up the gain and polarity of the com-
1
mand with;
Pr5C (Torque command input gain)
Pr5D (Torque command input reversal)
• Offset and filter cannot be set up.
• Becomes to the torque command input (TRQR).
• Set up the gain and polarity of the command with;
Pr5C (Torque command input gain)
Pr5D (Torque command input reversal)
• Offset and filter cannot be set up.
• Becomes to the analog torque limit input to CCW
(CCWTL).
• Limit the CCW-torque by applying positive voltage
(0 to +10V) (Approx.+3V/rated torque)
• Invalidate this input by setting up Pr03 (Torque limit
selection) to other than 0.
.
. =
23[mV]
/
I/F circuit
AI
P.162
)
167

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents