Parameter Setup
PrNo.
Title
46
Reversal of pulse
*
output logic
<Notes>
• For parameters which No. have a suffix of "*", changed contents will be validated when you turn on the
control power.
182
Setup
range
0 to 3
You can set up the B-phase logic and the output source of the pulse output (X5 OB+
<0>
: Pin-48, OB– : Pin-49). With this parameter, you can reverse the phase relation
between the A-phase pulse and the B-phase pulse by reversing the B-phase logic.
Setup
A-phase
value
(OA)
B-phase(OB)
<0>, 2
non-reversal
B-phase(OB)
1, 3
reversal
Pr46
<0>
1
2 *1
3 *1
*1 The output source of Pr46=2, 3 is valid only at full-closed control.
Function/Content
at motor CCW rotation
B-phase logic
Non-reversal
Reversal
Non-reversal
Reversal
Standard default : < >
at motor CW rotation
Output source
Encoder position
Encoder position
External scale position
External scale position