You can set up the torque limiting method for CCW/CW direction.
<1>
Setup value
0
<1>
2
3
When the setup value is 0, CCWTL and CWTL will be limited by Pr5E (1st torque
limit setup). At the torque control, Pr5E becomes the limiting value for CCW/CW
direction regardless of the setup of this parameter.
In linear drive application, you can use this over-travel inhibiting function to inhibit the
0 to 2
motor to run to the direction specified by limit switches which are installed at both ends
<1>
of the axis, so that you can prevent the work load from damaging the machine due to
the over-travel. With this input, you can set up the action of over-travel inhibit input.
input
Input
Connection to COM–
CCWL
(CN X5,Pin-9)
Valid
CWL
(CN X5,Pin-9)
Both CCWL and CWL inputs will be ignored, and over-travel inhibit function will be
Invalid
invalidated.
Err38 (Over-travel inhibit input protection) is triggered when either one
Valid
of the connection of CW or CCW inhibit input to COM– become open.
<Cautions>
1. When Pr04 is set to 0 and over-travel inhibit input is entered, the motor deceler-
ates and stops according to the preset sequence with Pr66 (Sequence at over-
travel inhibition). For details, refer to the explanation of Pr66.
2. When both of CCWL and CWL inputs are opened while Pr04 is set to 0, the driver
trips with Err38 (Overtravel inhibit input error) judging that this is an error.
3. When you turn off the limit switch on upper side of the work at vertical axis applica-
tion, the work may repeat up/down movement because of the loosing of upward
torque. In this case, set up Pr66 to 2, or limit with the host controller instead of us-
ing this function.
0 to 9
You can set up the content of analog speed monitor signal output (SP : CN X5,
<3>
Pin43) and the relation between the output voltage level and the speed.
Setup value
Signal of SP
0
1
Motor actual
2
<3>
4
5
6
7
8
9
Function/Content
CCW
X5 CCWTL : Pin-16
Pr5E is a limit value for both CCW and CW direction
Set with Pr5E
When GAIN/TL-SEL input is open, set with Pr5E
When GAIN/TL-SEL input is shorted, set with Pr5F
Work
CW direction
CCW direction
Servo motor
Limit
Limit
switch
switch
Close
Normal status while CCW-side limit switch is not activated.
Open
Inhibits CCW direction, permits CW direction.
Close
Normal status while CW-side limit switch is not activated.
Open
Inhibits CW direction, CCW direction permitted.
Relation between the output voltage level and the speed
speed
Command
speed
Standard default : < >
CW
X5 CWTL : Pin-18
Set with Pr5F
Driver
CCWL
CWL
Action
6V / 47 r/min
6V / 188 r/min
6V / 750 r/min
6V / 3000 r/min
1.5V / 3000 r/min
6V / 47 r/min
6V / 188 r/min
6V / 750 r/min
6V / 3000 r/min
1.5V / 3000 r/min