command
mode
2
9
Error cod
bit7
6
0 : Normal
1 : Error
• Output value of speed and torque are in 16 bit and deviation in 32 bit.
• Unit and sign of the output data is as same as that of command No. 24 (command = 2, mode = 4), 25 (mode = 5)
and 26 (mode = 6).
command
mode
2
A
Error cod
bit7
6
0 : Normal
1 : Error
• Meaning of each bit of control mode, status, input signal, output signal and alarm data is as same as that of command
No. 20 (command = 2, mode = 0), 27 (mode = 7) and 28 (mode =8).
• Read out of Present Speed, Torque and Deviation Counter
Reception data
0
axis
9
checksum
5
4
Command error
RS485 error
• Read out of Status, Input Signal and Output Signal
Reception data
0
axis
A
checksum
5
4
Command error
RS485 error
2
3
2
2
3
2
[Supplement]
Transmission data
9
axis
9
2
data L
(speed) H
data L
(torque) H
data L
(deviation) H
error code
checksum
1
0
Transmission data
0Dh
axis
A
2
control mode
status
input signal L
input signal H
output signal L
output signal H
alarm data L
alarm data H
error code
checksum
1
0