Noise Filter for Signal Lines *
Install noise filters for signal lines to all cables (power cable, motor cable, encoder cable and interface cable)
* In case of D-frame, install 3 noise filters at power line.
Option part No.
Manufacturer's part No.
DV0P1460
ZCAT3035-1330
39±1
34±1
Grounding
(1) Connect the protective earth terminal (
control box without fail to prevent electrical shocks.
(2) Do not make a joint connection to the protective earth terminals (
protective earth.
Ground-Fault Breaker
Install a type B ground fault breaker (RCD) at primary side of the power supply.
<Note>
For driver and applicable peripheral equipments, refer to P.32 "Driver and List of Applicable Peripheral
Equipments" of Preparation.
Driver and List of Applicable Peripheral Equipments (EC Directives)
Refer to P.28 to 41, "System Configuration and Wiring"
Conformity to UL Standards
Observe the following conditions of (1) and (2) to make the system conform to UL508C (File No. E164620).
(1) Use the driver in an environment of Pollution Degree 2 or 1 prescribed in IEC60664-1. (e.g. Install in the
control box with IP54 enclosure.)
(2) Install a circuit breaker or fuse which are UL recognized (LISTED
and the noise filter without fail.
For the rated current of the circuit breaker or fuse, refer to P.32, "Driver and List of Applicable Peripheral
Equipments" of Preparation.
Use a copper cable with temperature rating of 60˚C or higher.
Tightening torque of more than the max. values (M4:1.2N
(3) Over-load protection level
Over-load protective function will be activated when the effective current exceeds 115% or more than the
rated current based on the time characteristics. Confirm that the effective current of the driver does not
exceed the rated current. Set up the peak permissible current with Pr5E (Setup of 1st torque limit) and
Pr5F (Setup 2nd torque limit).
Manufacturer
TDK Corp.
<Caution>
Mass: 62.8g
Fix the signal line noise filter in place to
eliminate excessive stress to the cables.
) of the driver and the protective earth terminal (PE) of the
). 2 terminals are provided for
marked) between the power supply
m, M5: 2.0N
m) may break the terminal block.