P098

Analog and PWM Output Voltage Compensation

"0 to 10 V voltage signal" and "output status signal (PWM)" can be compensated.
Data setting range (%) 25 to 100 (increment = 1%)
■ Adjustment range (full-scale)
・Analog output voltage signal:3.75 to 10 (V)
・PWM signal
Related parameters: P090, P097
P099
Lower Frequency Limit
Upper Frequency Limit
P100
Upper limit and lower limit of output frequency can be set.
■ Parameter P099: Lower Frequency Limit
Data setting range
(Hz)
■ Parameter P100: Upper Frequency Limit
Data setting range
(Hz)
・When the upper frequency limit is lower than the maximum output frequency
(parameter P008), the upper frequency takes precedence.
・When the lower frequency limit is higher than the upper frequency limit
(reverse run setting), the latter takes precedence.
・The inverter may accelerate/decelerate depending on settings when data is
changed during operation.
Related parameters: P005, P008
:56.3 to 75 (%)
0.5 to 400.0
0.5 to 400.0