Jog Function - Panasonic VF200 Instruction Manual

Table of Contents

Advertisement

Appendix Function Parameter List

■JOG Function

Micro operations such as position adjustment can be performed with external
control signals.
Signal input terminals for controlling micro operation from external devices
can be set with parameter P036 to P040.
But Run Command Select (parameter P003) should be set through external
control.
・Turn the signal input ON, and it will enter JOG operation mode.
・JOG operation is performed according to "P042: JOG Frequency", "P043:
JOG Acceleration Time" and "P044: JOG Deceleration Time" settings, after
run/stop and forward/reverse run signals are input with terminal No.2 and
No.3.
< Example > When SW1 (parameter P036 = 3) is set to JOG function and run
command select (parameter P003 = 2) is used
Note 1) During JOG operation, please turn the JOG select signal ON (time B)
and then turn the run signal ON.
Note 2) During reverse run operation, please turn the reverse run signal ON
(time A) and then turn the run signal ON.
Related parameters: P042 to P044
176