·If fault trip occurs, the alarm LED will light up.
·Monitor function "n008: Alarm Type" can be used to identify the type of the
current alarm.
·When alarm LED operation select (parameter P147) is set to "1" and several
alarms occur simultaneously, the alarm display order is as follows.
(If a higher-priority alarm is in operation, it will still be displayed even if a
lower-priority alarm enters.)
·When settings of "P090 to P092: Output TR1, TR2 and Ry Function Select"
are set to "11", it can be output to the external devices as alarm signal.
Related parameters: P148, P149
P148

Upper Voltage Limit of Alarm LED

When alarm LED operation select is set to "1" or "2", the upper voltage limit to
judge output voltage fault alarm can be set with this parameter.
If output voltage of inverter is higher than setting value, the alarm LED will
flicker as output voltage fault alarm.
Data setting range (V) 0.1 to 600.0
Related parameter: P147
Abnormal
When cooling fan abnormality occurs, the alarm LED
cooling fan
will flicker.
alarm
Appendix Function Parameter List
259