Appendix Function Parameter List
■ Multi-speed SW Function
SW function is set so that it is used as multi-speed function.
Multi-speed function select is set with parameter P045.
・When all SWs are set to multi-speed function and 16-speed operation is
performed, the four SWs with lower No. are valid as multi-speed command
SW.
(Set "SW1 to SW5" to multi-speed function → Use SW1, SW2, SW3 and
SW4 as multi-speed command.)
・ Read "P045: Multi Speed Function Select" carefully before using this function.
(Refer to page 165)
Related parameters: P045 to P086
■ Reset Function
Fault stop status can be reset through external control if an inverter fault trip
(stop) occurs.
When a fault trip occurs and SW signal input is turned ON, the fault trip status
will be cleared if the SW signal input is turned OFF.