8. Setting Modes and Copy Functions of Built-in Memory

8.1 Setting Modes and Copy Functions of
Built-in Memory
For VF200 inverter, both of its unit and operation panel are equipped with
built-in memory as well as "Parameter Copy Function". When operation panel
is removed, the data inside can be copied to other inverter units.
The inverter provides up to 4 parameter copy functions, which are located
behind P182 in "Function Setting Mode" and displayed as "CPY1" to "CPY4".
They can be enabled only by changing setting data. In addition, data in build-in
memory of panel can be checked in "Built-in Memory Setting Mode".
Copy
parameter
No.
CPY1
Upload function
CPY2
Download function
CPY3
Verification function
Built-in memory setting
CPY4
mode display select
102
Function name
Details
To upload parameter settings
from the unit to built-in memory
of operation panel.
To download parameter settings
from built-in memory of
operation panel to the unit.
To check if function parameters
in the unit are identical to those
in built-in memory of operation
panel.
To determine whether to display
built-in memory setting mode or
not.
Reference
page
P.107
P.109
P.111
P.113