P098£ºAnalog and PWM output voltage compensation
Used to compensate the output of "0~10V voltage signal" and "output state signal (PWM)".
Data setting range (%)
[Adjustment range (full scale value)]
•E Analog output voltage signal: 3.75~10(V)
•E PWM signal: 56.3~75(%)
P099£ºLower frequency clamp
P100£ºUpper frequency clamp
Used to set the upper and lower limits of the output frequency.
[Parameter P099: Lower frequency clamp]
Data setting range (Hz)
[Parameter P100: Upper frequency clamp]
Data setting range (Hz)
Note
•EIf the upper frequency clamp is lower than the maximum output frequency (parameter P008),
the upper frequency clamp will have the priority.
•EIf the lower frequency clamp is higher than the upper frequency clamp (reverse run setting),
the upper frequency clamp will have the priority.
110
25 to 100 (1% unit)
0.5 to 400.0
0.5 to 400.0
Related
parameters
Max. output frequency
(parameter P008)
Upper frequency
clamp
Output
(parameter P100)
frequency
(Hz)
0
Setting frequency signal 100%
Related
parameters
Ïà¹Ø
P090, P097
²ÎÊý
Lower frequency
clamp
(parameter P099)
Ïà¹Ø
P005, P008