■ 3-point mode 1
Output frequency(Hz)
■ 3-point mode 4
Output frequency(Hz)
· Settings for 3C1 to 3C6 don't affect the second feature.
· Factory settings of maximum output frequency and base frequency are both
50 Hz.
· Please consider the setting of Upper Frequency Limit (parameter P100)
when changing the maximum output frequency.
· In free mode or 3-point mode, please note that sharp
acceleration/deceleration or overcurrent may occur depending on setting
values and load state if change point frequency and voltage are changed
during operation.
·If change point frequency 1 or 2 is set to a value higher than base frequency,
the invert will still operate according to the base frequency setting.
· If change point frequency 2 is set to a value lower than change point
frequency 1, it w ill operate according to the setting of latter one.
· If change point voltage 1 or 2 is set below the torque boost value, it will
operate according to the setting value of "P007: Torque Boost".
· If change point voltage 2 is set to a value lower than change point voltage 1,
it will operate according to the setting of latter one.
· In 3-point mode, V/F curve (P006) corresponds to constant torque mode.
Even if the setting is square torque mode, constant torque mode still applies.
· It is invalid during vector control (P129 = "1").
Related parameters: P007 to P013, P100
Appendix Function Parameter List
■ 3-point mode 2
Output frequency(Hz)
■ 3-point mode 5
Output frequency(Hz)
■ 3-point mode 3
Output frequency(Hz)
■ 3-point mode 6
Output frequency(Hz)
149