4.7.2 Operating with Operation Panel - 2

·Forward/reverse run function: Forward/Reverse Run Button Operation Mode
(Parameter P003 = 1)
·Frequency setting: Potentiometer Setting Mode (Parameter P004 = 0)
■ Operating Example ①: Forward run operation at operating frequency of 25 Hz
1. Turn on the power.
The display part will be ON immediately after power-on.
(Operation Status Display Mode)
2. Set rotation direction.
Press
button to select forward run.
(Press
button to select reverse run.)
3. Start operation.
Press
button.
The inverter enters running status, but it can be only in 0V stop
status due to the frequency setting dial is in the MIN. position.
4. Adjust frequency.
Turn the frequency setting dial
motor starts to run. The value "25.0" indicates that the motor is
running at 25 Hz.
5. Input stop command.
Press
button. The motor starts to decelerate till to stop.
4. Operation Method (Basic Operation)
clockwise slowly till the