Winding Length - Panasonic VF200 Instruction Manual

Table of Contents

Advertisement

5. Control Status Monitor
n024
Unit Version
Panel Version
n025
·They show the firmware versions of VF200 unit and operation panel.
·The model code and version code are shown as follows.
About the version of VF200 unit and operation panel
·Operation status display varies depending on the combination of firmware
version of VF200 unit and operation panel.
Combination of firmware
versions
VF200 unit firmware version >
operation panel firmware
version (VF200 unit version
Ver.1.0X excluded)
VF200 unit firmware version ≤
operation panel firmware
version
Pulse Input Signal Detection Value
n026
·Display frequency detection value for pulse input signal of inverter.

Winding Length

n027
·It is used for the calculate result for winding length of pulse input signal when
the setting vale for "P036:SW1 Function Select" is 14.
・The calculate result of winding length is as follow.
Winding Length=
・The relation of winding and display is as follow.
When 1m to 9,999m, display as 1 to 9999.
When 10,000m to 99,999m, display as 10.00 to 9.999.
When 100,000m to 600,000m, display as 10.00 to 60.00.
・If set value of "P038:SW3 Function Select" as 14, the calculate value will be
cleared when SW3 is ON.
80
"Er2" will be displayed on the operation panel.
Press "↑" button to display VF200 unit firmware version.
Press "↓" button to display the operation panel firmware
version.
The version will be displayed as shown in the above figure.
(pulse value input to SW1)×(P181: Winding length radio)
Operation
1000

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents