Appendix Function Parameter List
P171
Recoil Frequency Band in Winding Mode
Percent of recoil frequency for frequency amplititude set with parameter P170
can be set with this parameter.
Setting range (%)
P172
Winding Mode Cycle
Time required for one cycle of winding mode control operation and the
acceleration time in one cycle can be set with these parameters.
■ Winding Mode Period
Setting range (sec)
■ Rise Time Coefficient in Winding Mode
Setting range (%)
The formulas of acceleration/deceleration time below can be acquired via
setting of P172 and P173.
Rise time of triangular-wave frequency = winding mode cycle (s) × rise time
coefficient of winding mode (%)
Drop time of triangular-wave frequency = winding mode cycle (s) × (100 -
rise time coefficient of winding mode (%))
P174
Pulse Input Signal Frequency
It is used when set "P87: PWM/pulse frequency signal select" to "2".
Please set pulse input count per second (pulse frequency) when it is max output
frequency.
Setting range (Hz)
272
0.0% to 100.0%
P173
0.0~3600
0.0~100.0
1~10000(Setting unit:1Hz)
Rise Time Coefficient in
Winding Mode