8.5 Parameter Verification Function

Refers to the function of making comparison and verification between setting
values of function parameters in the unit and those in built-in memory of
operation panel. The comparison and verification will start after setting value
"VEr" is set.
How to verify the parameters
1. Press
button to stop the inverter.
2. Press
button four times.
(If a password is set beforehand, please enter it. Refer to
parameter P150. )
3. Press
button.
4. Press
5. Press
button.(Display the current settings.)
6. Press
button to change the displayed value to "VEr".
7. Press
button to start verification.
The displayed value (VEr) is flickering during verification.
● If different data is checked out
If different data is checked out, displayed parameter No. will
flicker.
In this case, press
while
button to display data in built-in memory of
operation panel.
Press
button to start verification from the next data again.
Press
button to stop verification and "CPY3" is displayed.
After verification completion, "End" is displayed.
8. Setting Modes and Copy Functions of Built-in Memory
button to select "CPY3".
button to display data in the unit