Winding Mode Input Length - Panasonic VF200 Instruction Manual

Table of Contents

Advertisement

Appendix Function Parameter List
If the following functions start together with winding mode control function,
such function will take precedence. And what's more, winding mode control
will not start when the following functions operate.
Trial operation function
·
Automatic tuning function
·
Timer operation function
·
PID function
·

■ Winding mode input length

When set parameter "P169: Winding mode control select" to "1" or "2", set
parameter "P036: SW1 function select" to "14", and pulse input in SW1, length
can be calculated by "P181: Winding length magnification".
Winding length zero clearing
The calculate result will be displayed in n027.
·
Winding length =
Set "P038: SW3 function select" to "14", the calculate value will be cleared.
·
188
Pulse input
(n × Winding length radio)
1000
Pulse