Panasonic VF200 Instruction Manual page 161

Table of Contents

Advertisement

Appendix Function Parameter List
P010
Change Point Frequency 1
Change Point Voltage 1
P011
Change point 1 and 2 can be selected in 3-point mode of "P005: V/F Mode".
(It is valid only when parameter P005 is set to "3C".)
■ Parameter P010: Change Point Frequency 1
Data setting
range (Hz)
■ Parameter P011: Change Point Voltage 1
Data setting
range (%)
■ Parameter P012: Change Point Frequency 2
Data setting
range (Hz)
■ Parameter P013: Change Point Voltage 2
Data setting
range (%)
Read "P005: V/F Mode" carefully before setting.
·
Change point frequency 1 and 2 will operate according to the setting value
·
of base frequency when set to a value higher than base frequency.
Change point frequency 2 will operate according to the the setting value of
·
change point frequency 1 when set to a value lower than change point
frequency 1.
When setting "P007: Torque Boost", change point voltage 1 and 2 will
·
operate according to the setting value of torque boost if set to a value lower
than torque boost level.
Change point voltage 2 will operate according to the the setting value of
·
change point voltage 1 when it is set to below change point voltage 1.
Please note that sharp acceleration/deceleration or overcurrent may occur
·
depending on setting values and load status if data is changed during
operation.
Set as "3C1" to "3C6" of "P005: V/F Mode", P010 to P013 will change to fixed
·
value automatically, and can not be able to be changed.
Related paremeters: P005, P100, P007 to P009
154
0.5 to 400.0
0 to 100
0.5 to 400.0
0 to 100
P012
Change Point Frequency 2
Change Point Voltage 2
P013