Linear Speed Multiplier; Alarm Led Operation Select - Panasonic VF200 Instruction Manual

Table of Contents

Advertisement

Appendix Function Parameter List
P146

Linear Speed Multiplier

When setting value in "P145: Operation Status Monitor" is "1" (linear speed),
multiplier relative to output frequency can be set.
■ Parameter P146: Linear Speed Multiplier
Data setting range
<Setting example> When linear speed is displayed
·Linear speed exceeding "9999" is displayed as "9.9.9.9".
Related parameter: P145
P147

Alarm LED Operation Select

Alarm LED operation of the panel can be selected with this parameter.
Setting value
0
1
2
3
4
5
258
0.1 to 100.0
Linear speed (m/min) = F (Hz) × K (multiplier)
·To display linear speed 25 (m/min) at 50 Hz, set multiplier
(K) to "0.5".
Function name
N/A
N/A (The LED lights up when fault trip occurs)
When any of the specified conditions (output voltage
Full monitor
fault, overload, temperature abnormality, timer
alarm
operation stop and cooling fan abnormality) is
satisfied, the alarm LED will flicker.
Output voltage
When the setting value (P147) is reached, the alarm
Fault alarm
LED will flicker.
When the setting value (P148) is reached, the alarm
Overload alarm
LED will flicker.
Abnormal
When heat sink temperature rises above 80 °C, the
temperature
alarm LED will flicker.
alarm
When timer operation is complete, the alarm LED will
flicker.
Timer stop
(The signal is linked with timer operation function.
signal
When ∞ is displayed, the alarm LED will not flicker.)
Details of Function