■ Frequency

When frequency and parameter P040 are set to "digital setting with operation
panel (P004 = 1)" and "11" respectively, SW3 and SW4 can be used to change
frequency while SW5 to save this frequency.
・It is forced to be used as function input terminal of "SW3: frequency increase
SW", "SW4: frequency decrease SW" and "SW5: frequency memory SW" after
parameter P040 is set to "11".
· SW3: During ON, frequency increases. (During OFF, the existing frequency
is held.)
· SW4: During ON, frequency decreases. (During OFF, existing frequency is
held.)
· SW5: Turn ON once and OFF again to save the frequency at that time.)
(The frequency can be saved even if the power is turned OFF.)
Note 1) The operating frequency will not be changed when both
(SW3) and
etc).
Note 2) The operating frequency will not be saved when "frequency memory
operation of SW5" and "frequency setting in frequency setting mode"
on the operation panel are not performed.
/
Setting Function
button (SW4) are turned OFF or ON (i.e. in A or B area
Appendix Function Parameter List
button