P045£ºMulti speed function select
Used to set each control function when SW1~5 (control circuit terminals No.4~8) are set as multi
speed function with parameters P036~P040, and SW2 (control circuit terminal No.5) is set as pulse
counter input function with parameter P037.
Data setting
value
Set to multi speed frequency operation function
0
1
Set to 2nd, 3rd and 4th acceleration and deceleration operation function
Set to acceleration and deceleration link multi speed frequency operation
2
function
Set to timer's multi speed frequency operation function
3
Set to timer's acceleration and deceleration link multi speed frequency
4
operation function
Set to pulse input multi speed frequency operation function
5
Set to pulse input acceleration and deceleration link multi speed frequency
6
operation function
When setting value is 0 to 2, use SW1~5(control circuit terminals No.4~8) after they are set to "
multi speed function" (setting value "0") with parameter P036~P040.
When setting value is 3 to 4, SW1~5(control circuit terminals No.4~8) are invalid even if they are
set to "multi speed function" with parameter P036~P040.
When setting value is 5 to 6, use SW2 (control circuit terminal No.5) after it is set to "pulse counter
input function" (setting value "11") with parameter P037.
Multi speed frequency operation function (setting value "0")
2nd, 3rd and 4th acceleration and deceleration operation function (setting value"1")
Acceleration and deceleration link multi speed frequency operation function (setting value "2")
[Setting value "1": Multi speed frequency operation function]
Multi speed frequency operation of SW can reach 16 speed at most. Acceleration and deceleration
time is fixed to 1st acceleration and deceleration time. (parameters P001 and P002).
When all setting values of SW function of SW1~5 are "0" (multi speed SW input function), four SW
in order with smaller SW No. are valid as multi speed command SW.
2nd ~16th speed frequency is set with parameter P046~P060.
[Setting value "2" : 2nd , 3rd and 4th acceleration and deceleration operation function]
Frequency is fixed to 1st speed frequency. SW can be used to change at most four acceleration
and deceleration time for operating the inverter.
2nd ~4th acceleration and deceleration time are set with parameters P061~P066.
[Setting value "3": Acceleration and deceleration link multi speed frequency operation function]
Using 4 SW to link at most 16 speed and 4 acceleration and deceleration time for applying multi
speed frequency operation.