Software Sw Setting For Cs Remote Care - Konica Minolta bizhub C450 Service Manual

Hide thumbs Also See for bizhub C450:
Table of Contents

Advertisement

Field Service Ver. 1.0 Mar. 2005
10.7.3

Software SW setting for CS Remote Care

NOTE
• SW bits data are written into the NVRAM every time a change is made. In case you
changed bit data by accident, be sure to restore the previous state.
A. Input procedure
1. Select Service Mode → "CS Remote Care" → "Detail Setting", and touch "Software
Switch Setting" key.
2. Touch "Switch No." key, and input the SW number (two digits) using the 10-Key Pad.
3. Touch "Bit Assignment", and select SW bit number using the arrow keys, and input 0 or
1 using the 10-Key Pad.
(For setting by hexadecimal numbers, touch "HEX Assignment" key, and input using the
1-Key Pad or A to F keys.)
4. Touch "Fix" key.
NOTE
• About functions of each switch, see to "B.List of software SW for CS Remote
Care."
B. List of software SW for CS Remote Care
NOTE
• Do not change any bit not described on this table.
SW No.
Bit
SW 01
0
Dial Mode
1
Line for send only
2
Reservation
3
Reservation
4
Baud rate
5
6
7
SW 02
0
Auto call on SC occurrence
1
Auto call on date specification
2
Auto call on the part replacement
3
Auto call on the drum replacement
Auto call on the periodic maintenance
4
(PM)
5
Auto call on the IU Life
6
Auto call of the IR shortage
Auto call on the zero reset of the fixed
7
parts replacement.
SW 03
0
Reservation
1
Auto call on the toner supply
2
Reservation
3
Auto call on the waste toner bottle full
4 to 7 Reservation
SW 04
0 to 7 Reservation
Functions
10. Service Mode
0
1
Pulse
Tone
No
Yes
*1
*1
*1
*1
*1
*1
*1
*1
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Default
1
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
0
1
0
1
0
0
249

Hide quick links:

Advertisement

Table of Contents
loading