Model Number Legend and Standard Models

Model Number Legend

Models with Screw Terminal Blocks
E5DC-@@ @ @ @ M-@@@ (Example: E5DC-RX0ASM-015)
−− − − − − −−−
A
B C D E
A
B
No. of
Model
Control
auxiliary
output 1
outputs
E5DC
RX
QX
*1 CX
0
2
*1. The control output can be used as a simple transfer output for the Digital Temperature Controllers manufactured in July 2014 or later.
*2. Option 000 can be selected only if two auxiliary outputs are selected.
*3. Options 002 and 017 can be selected only if the control output is a relay output or voltage output and two auxiliary outputs are selected.
*4. Option 015 cannot be selected if the control output is a relay output or voltage output and two auxiliary outputs are selected.
*5. Options 016 can be selected only if the control output is a linear current output and two auxiliary outputs are selected.

List of Models

No. of auxiliary
Control output
outputs
---
Relay output
2
---
Voltage output
(for driving SSR)
2
---
Linear current
output
2

Heating and Cooling Control

Using Heating and Cooling Control
A Control Output Assignment
An auxiliary output is used as the cooling control output.
F
C
D
E
Power
Terminal
Input
supply
type
type
voltage
A
D
S
U
M
*2
*3
*4
*5
*3
Options
HB alarm and HS
No. of event inputs
alarm
---
---
Detection for single-
phase heater
1
---
---
Detection for single-
phase heater
1
---
---
1
F
Options
22.5 mm wide and mounts to DIN Track
Control output 1
Relay output
Voltage output
(for driving SSR)
Linear current output *1
Screw terminal blocks (Main Unit and Terminal Unit together)
Main Unit only (no Terminal Unit)
HB alarm and HS alarm
000
---
002
1
015
---
016
---
017
1
Power supply voltage
Communications
E5DC-RX0ASM-015
RS-485
E5DC-RX0AUM-015
E5DC-RX2ASM-000
---
E5DC-RX2AUM-000
E5DC-RX2ASM-002
RS-485
E5DC-RX2AUM-002
E5DC-RX2ASM-017
---
E5DC-RX2AUM-017
E5DC-QX0ASM-015
RS-485
E5DC-QX0AUM-015
E5DC-QX2ASM-000
---
E5DC-QX2AUM-000
E5DC-QX2ASM-002
RS-485
E5DC-QX2AUM-002
E5DC-QX2ASM-017
---
E5DC-QX2AUM-017
E5DC-CX0ASM-015
RS-485
E5DC-CX0AUM-015
E5DC-CX2ASM-000
---
E5DC-CX2AUM-000
E5DC-CX2ASM-015
RS-485
E5DC-CX2AUM-015
E5DC-CX2ASM-016
---
E5DC-CX2AUM-016
B Control
If PID control is used, you can set PID control separately for heating
and cooling.
This allows you to handle control systems with different heating and
cooling response characteristics.
Meaning
Control output 2
None
None
None
None
2 (one common)
100 to 240 VAC
24 VAC/DC
Universal input
Communications Event input
---
RS-485
RS-485
---
---
Model
Model
Power supply voltage
100 to 240 VAC
24 VAC/DC
E5DC-RX0DSM-015
E5DC-RX0DUM-015
E5DC-RX2DSM-000
E5DC-RX2DUM-000
E5DC-RX2DSM-002
E5DC-RX2DUM-002
E5DC-RX2DSM-017
E5DC-RX2DUM-017
E5DC-QX0DSM-015
E5DC-QX0DUM-015
E5DC-QX2DSM-000
E5DC-QX2DUM-000
E5DC-QX2DSM-002
E5DC-QX2DUM-002
E5DC-QX2DSM-017
E5DC-QX2DUM-017
E5DC-CX0DSM-015
E5DC-CX0DUM-015
E5DC-CX2DSM-000
E5DC-CX2DUM-000
E5DC-CX2DSM-015
E5DC-CX2DUM-015
E5DC-CX2DSM-016
E5DC-CX2DUM-016
E5DC
---
---
---