Model Number Legend and Standard Models
Model Number Legend
Models with Screw Terminal Blocks
E5EC-@@ 4 @ 5 M -@@@ (Example: E5EC-RX4A5M-000)
−− − − − − −−−
A
B C D E
E5AC-@@ 4 @ 5 M -@@@ (Example: E5AC-RX4A5M-000)
−− − − − − −−−
A
B C D E
A
Model
Control outputs
1 and 2
E5EC
E5AC
RX
QX
*2 CX
QQ
QR
RR
*2 CC
*2 CQ
PR
Control outputs 1 and 2
For RX,
QX, QQ,
For CX or
QR, RR, or
CC
CQ
Selectable Selectable Selectable
Selectable Selectable
Option
Selectable
selection
conditions
*1
Selectable
Selectable
Selectable
Selectable
Selectable Selectable
*1. The options that can be selected depend on the type of control output.
*2. The control output cannot be used as a transfer output.
*3. A model with four auxiliary outputs must be selected.
Note: Draw-out-type models of the E5EC and E5AC are available. Ask your OMRON representative for details.
Heating and Cooling Control
Using Heating and Cooling Control
A Control Output Assignment
If there is no control output 2, an auxiliary output is used as the cooling control output.
If there is a control output 2, the two control outputs are used for heating and cooling.
(It does not matter which output is used for heating and which output is used for cooling.)
B Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
F
F
B
C
D
No. of
Power
Terminal
auxiliary
supply
type
outputs
voltage
*3 4
A
D
5
For PR
E
F
Input
Options
type
Control output 1
Relay output
Voltage output
(for driving SSR)
Linear current output
Voltage output
(for driving SSR)
Voltage output
(for driving SSR)
Relay output
Linear current output
Linear current output
Position-proportional relay output
4 (auxiliary outputs 1 and 2 with same common and
auxiliary outputs 3 and 4 with same common)
Screw terminal blocks (with cover)
M
HB alarm
and
Communications
HS alarm
000
---
004
---
005
---
2
009
(for 3-phase
heaters)
010
1
011
1
013
---
014
---
E5EC/E5EC-B/E5AC
Meaning
48 × 96 mm
96 × 96 mm
Control output 2
None
None
None
Voltage output
(for driving SSR)
Relay output
Relay output
Linear current
output
Voltage output
(for driving SSR)
Position-
proportional relay
output
100 to 240 VAC
24 VAC/DC
Universal input
Event
Remote
Transfer
inputs
SP Input
output
---
---
---
RS-485
2
---
---
4
---
RS-485
2
---
---
4
---
---
6
Provided. Provided.
---
6
Provided. Provided.
RS-485
4
Provided. Provided.
---
---
---
---
---