2
4. Remove the left guide [D] ( x 2) and scanner left cover [E] (hook x 2).
5. Place the DF exposure glass [F] on the glass holder.
• When installing the DF exposure glass, make sure that the side of the DF exposure glass with
two black points faces down.
• Do not hold the Mylar strip when installing the DF exposure glass.
• Make sure that there is no gap between the two Mylar strips and the scanner frame. If there is
any gap between them, dust may fall into the scanner unit.