Ricoh D069 Field Service Manual page 230

Hide thumbs Also See for D069:
Table of Contents

Advertisement

3. Appendix: Service Call Conditions
[0D05]
B
3
[50A1]
B
[50A2]
B
Self-diagnostic error: HDD (Hard Disk Drive)
[XXXX]: Detailed error code
822
When the main switch is turned on or starting the self-diagnostic, the HDD stays busy for
the specified time or more.
[3003]
C
[3004]
C
823
Self-diagnostic Error: NIB
[6101]
C
38
Timer error between ASIC and CPU
The CPU checks if the ASIC timer
works properly compared with the
CPU timer. If the ASIC timer does not
function in the specified range, this SC
code is displayed.
Video bridge device (ASIC) error 1
The CPU does not detect the video
bridge device.
Video bridge device (ASIC) register error 1
The CPU detects the video bridge
device, but detects error data from the
video bridge device.
Timeout error
Command error
MAC address check sum error
The result of the MAC address check
sum does not match the check sum
stored in ROM.
• System firmware problem
• Defective RAM-DIMM
• Defective controller
• Reinstall the controller system firmware.
1. Replace the RAM-DIMM.
2. Replace the controller board.
• Defective I/F between the video bridge
device and i-controller
1. Replace the i-controller.
• Defective I/F between the video
bridge device and i-controller
1. Replace the i-controller.
• Loose connection
• Defective HDD
• Defective controller
1. Check that the HDD is correctly
connected to the controller.
2. Replace the HDD.
• Replace the controller.
• Defective controller
1. Replace the controller.

Advertisement

Table of Contents
loading

This manual is also suitable for:

D068D067D072

Table of Contents