Ricoh D069 Field Service Manual page 278

Hide thumbs Also See for D069:
Table of Contents

Advertisement

5. Appendix: SP Mode Tables
Start
Specifies the start setting for the summer time mode.
There are 8 digits in this SP. For months 1 to 9, the "0" cannot be input in the first digit, so
the eight-digit setting for -2 or -3 becomes a seven-digit setting.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [1 to 5]
4th digit: The day of the week. [0 to 6 = Sunday to Saturday]
003
5th and 6th digits: The hour. [00 to 23]
7th digit: The length of the advanced time. [0 to 9 / 1 hour /step]
8th digit: The length of the advanced time. [0 to 5 / 10 minutes /step]
For example: 3500010 (EU default)
5
The timer is advanced by 1 hour at am 0:00 on the 5th Sunday in March
• The digits are counted from the left.
• Make sure that SP5-307-1 is set to "1".
End
Specifies the end setting for the summer time mode.
There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
004
4th digit: The day of the week. [0 to 6 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8th digits must be set to "00".
• The digits are counted from the left.
• Make sure that SP5-307-1 is set to "1".
Access Control
5401
When installing the SDK application, SAS (VAS) adjusts the following settings. DFU
103 DocAcl
104 Authentication Time
86
-
-
-
-
CTL
CTL
[ 0 to 255 / 0 / 1 /step]

Advertisement

Table of Contents
loading

This manual is also suitable for:

D068D067D072

Table of Contents