5. Appendix: SP Mode Tables
Selects which version of the Scan Router application program, "Light" or "Full
(Professional)", is installed.
[0 to 1 / 0 / 1 /step]
001
0: Light version (supplied with this machine)
1: Full version (optional)
Device Setting
The NIC and USB support features are built into the GW controller. Use this SP to enable
5985
and disable these features. In order to use the NIC and USB functions built into the
controller board, these SP codes must be set to "1".
5
001 On Board NIC
002 On Board USB
SP Print Mode
In the SP mode, press Copy Window to move to the copy screen, select the paper size,
5990
then press Start. Select A4/LT (Sideways) or larger to ensure that all the information prints.
Press SP Window to return to the SP mode, select the desired print, and press "EXECUTE".
001 All (Data List)
002 SP (Mode Data List)
003 User Program
004 Logging Data
005 Diagnostic Report
006 Non-Default (Prints only SPs set to values other than defaults.)
132
[0 to 2 / 0 / 1 /step]
0: OFF, 1: ON, 2: ON: Limited
When the "Function limitation" is set, "On board NIC" is limited only
for the @Remote or LDAP/NT authentication.
• Other network applications than @Remote or LDAP/NT
authentication are not available when this SP is set to "2". Even
if you can change the initial settings of those network
applications, settings may not actually work.
[0 or 1 / 0 / 1/step]
0: OFF, 1: ON
SMC Print