5. Appendix: SP Mode Tables
5901
Printer Free Run
5901 1 Executes the free run. Press "ON" to start; press "OFF" to stop.
5902
Test Pattern Print
5902 1
5907*
Plug & Play Setting
Selects the brand name and production name for the Plug and Play function. These names
are stored in the NVRAM. When the NVRAM data is corrupted, select these names once
5907 1
again. Use the right-arrow or left-arrow key to scroll through the list of brand names. To
select a brand name, press the OK key. An asterisk (*) indicates which manufacture is
currently selected.
5
5912*
PCU Alarm Counter (Printout)
Specifies the PCU alarm level. The PCU alarm is issued when the following condition is
met:
5912 1
PAc x 1000 >= PCUc
where PAc is the value specified in this SP and PCUc is the PCU counter. When you specify
0 (zero), the PCU alarm is deactivated.
5990
SMC Print
5990 1 All
5990 2 SP
5990 3 User Program
5990 4 Logging Data
5990 5 Big font
SP6-XXX (Peripherals)
ADF Adjustment (
6006*
NOTE: Available menus depend on the machine model and its configuration.
190
"Test Pattern Print" in this section.
"DF Image Adjustment" in the "Adjusting Copy Image Area")
[0 to 255 / 45 / 1/step]
"SMC Print" in this section.