Ricoh D069 Field Service Manual page 479

Hide thumbs Also See for D069:
Table of Contents

Advertisement

6-7
Not used
IP Fax Switch 08 [SP No. 1-111-009]
No.
FUNCTION
T1 timer adjustment
Adjusts the T1 timer.
The default is "00" (35 seconds).
0-1
Bit 1: 0, Bit 0: 0 = 35 sec
Bit 1: 0, Bit 0: 1 = 40 sec
Bit 1: 1, Bit 0: 0 = 50 sec
Bit 1: 1, Bit 0: 1 = 60 sec
T4 timer adjustment
Adjust the T4 timer.
The default is "00" (3 seconds).
2-3
Bit 3: 0, Bit 2: 0 = 3 sec
Bit 3: 0, Bit 2: 1 = 3.5 sec
Bit 3: 1, Bit 2: 0 = 4 sec
Bit 3: 1, Bit 2: 1 = 5 sec
T0 timer adjustment
Bit 5: 0, Bit 4: 0 = 75 sec
4-5
Bit 5: 0, Bit 4: 1 = 120 sec
Bit 5: 1, Bit 4: 0 = 180 sec
Bit 5: 1, Bit 4: 1 = 240 sec
6-7
Not used
Do not change these settings.
COMMENTS
-
-
Adjusts the fail safe timer. This timer sets the interval
between "setup" data transmission and T.38 phase
decision. If your destination return is late on the
network or G3 fax return is late, adjust the longer
interval timer.
The default is "00" (75 seconds).
Do not change these settings.
Bit Switches
7
287

Advertisement